Communications for today... and tomorrow.
TekTip: Troubleshooting the IR704BD and PK724
The following are troubleshooting steps for models IR704BD/PK724. If this system fails to operate as required check the following:
- Entire system dead: Check 16 volts at transformer secondary; wiring between amplifier and transformer; amplifier connections at terminals T1 and T2; 117VAC at transformer primary.
- No sound from one speaker: Check speaker volume control; speaker MON button; wiring to terminals 3 and 4; wiring to amplifier terminals 3 and 4.
- Squealing or howling: Check volume control set too high; speakers installed too close together or on a common wall; twisted pair wiring not used.
- Unable to talk or monitor: Check speaker volume turned off; wiring to terminals 1 and 2; wiring to amplifier terminals 1 and 2.
- Unable to talk to door: Check the connections to outside speakers; wiring to amplifier terminals A and B; volume set too low.
- Unable to listen to door: Check amplifier terminals 1 and 2 shorted to terminal 4 or ground; volume set too low.
- No call tone: Check the connections at outside speaker push button; wiring to amplifier terminal A and Z (if installed).

(Jan. 1986)
TekTone® Sound & Signal Mfg., Inc.
277 Industrial Park Road
Franklin, NC 28734
USA
Phone: (828) 524-9967
Fax: (828) 524-9968
Sales: (800) 327-8466
Tech Support: (800) 332-6608