In this issue, the featured product is the Tek-ENTRY® Series Apartment Intercom System and TA205B Suite Phone. If this system fails to operate properly, check the following points:

  1. Entire system dead: Check 117 volts AC at transformer primary; 16 VAC at transformer secondary; wiring to amplifier terminals T and K.
  2. No talk at suite: Check wiring to terminal A and B shorted or open; wiring to entrance panel speaker shorted or open; suite phone may be checked by replacement.
  3. No listen at suite: Check wiring terminals C and D shorted or open; wiring to entrance panel microphone shorted or open; suite phone defective.
  4. No door operation: Check wiring to door release defective; door button on suite phone.
  5. No call tone: Check wiring to amplifier terminal Z; entrance panel push buttons; wiring to suite phones terminal X.
  6. Excessive hum or distortion: Check wiring installed too close to electrical wiring or devices; amplifier installed too close to transformers or electrical devices; twisted pair wiring not used as required; amplifier volume control set too high.
  7. Radio interference: Check connection from amplifier terminal G to electrical ground.

TA205B wiring

(Jul. 1985)


TekTone® Sound & Signal Mfg., Inc.
277 Industrial Park Road Franklin, NC 28734 USA
Phone: (828) 524-9967 Fax: (828) 524-9968
Sales: (800) 327-8466 Tech Support: (800) 332-6608